#979 closed defect (fixed)
SIGSEGV signal caught when External Material is included
Reported by: | Owned by: | Lars Gullik Bjønnes | |
---|---|---|---|
Priority: | high | Milestone: | 1.3.2 |
Component: | frontend-qt2 | Version: | 1.3.1 |
Severity: | normal | Keywords: | crash |
Cc: |
Description
I've installed the lyx 1.3.1 rpm package for suse 8.1
When I include any external material (like a xfig figure, or a RasterImage),
lyx exits and shows the next message:
lyx: SIGSEGV signal caught
Sorry, you have found a bug in LyX. Please read the bug-reporting instructions
in Help->Introduction and send us a bug report, if necessary. Thanks
!
LyX: Intentando guardar el documento newfile1.lyx
/home/rafa/newfile1.lyx.emergency
La operación de guardado parece ser exitosa. Pfiu.
Bye.
When LyX is run again, there is an emergency copy of the document where the
desired file is included.
Change History (5)
comment:1 by , 21 years ago
Component: | build → menus |
---|
comment:2 by , 21 years ago
Component: | menus → frontend-qt2 |
---|---|
Keywords: | crash added |
Milestone: | → 1.3.2 |
Resolution: | → fixed |
Status: | new → closed |
comment:5 by , 21 years ago
I assure you that the APPLY button doesn't work.
In the external dialog, I can edit or preview the file, but when the apply
button is pushed, nothing happens.
In the meantime, I'm including my fig files as figures, so I don't need the
External Dialog, but I'd like to tell you it doesn't work properly, at leart
with the distribution suse 8.1
Thanks
It's fixed in 1.3.2. In the meantime, please use apply or close and
do NOT use "OK" in the External dialog.